Approval agrees what an SOP says; the effective date is when people start working to it. The days between are for getting them ready.

Say revision 05 of the gowning SOP is approved at 15:00 and made effective at 15:00. The night shift comes in at 22:00, has not been trained on the new sequence, and finds revision 04 still in the binder at the changing room door. From 15:00 onward everything they do by the old text is a deviation on paper, though they did nothing wrong.

The 2011 text of EU GMP Chapter 4 says documents containing instructions should be approved, signed and dated, and that the effective date should be defined. It gives no number of days between the two dates; the site procedure does.

Use the gap to train every shift and record it, people on leave included; to swap the controlled copies at the point of use and count the old ones back in; and to update the document register on the effective date, no earlier.

How long depends on the change. A corrected reference can go live in a day or two, while a changed gowning sequence has to be shown to each shift first.

How many days does your document procedure leave between approval and effective date?

Topics

Industries

Related

More on this subject

One more market is one more SKU to run

'Same product, new box' brings new artwork and codes to control, a registration that may need stability data at other climatic conditions, possibly a new pack to qualify, and one more changeover in the weekly plan. Cost the SKU as a small project before a launch date is promised.

InsightRead

OOS and OOT: two results, two different triggers

An out-of-specification result falls outside the specification or acceptance criteria and starts with a laboratory assessment. An out-of-trend result is inside the limits but breaks the pattern of earlier results. EU GMP Chapter 6 says both should be addressed and investigated, which needs data recorded so that trends can be evaluated.

InsightRead

Out of tolerance at calibration: the look-back, then the adjustment

When an instrument fails its as-found check, adjusting it straight away leaves two things unasked: how long it was wrong and what relied on it. Record the as-found values, find the last calibration that passed, list what depended on the readings since, have QA assess the impact, then adjust and review the calibration interval.

InsightRead