The blender in a tablet plant can be part of the product's registration dossier, by type and working capacity.
It sits in Module 3 of the CTD. ICH M4Q(R1) divides the body of data into the drug substance (3.2.S), the drug product (3.2.P), appendices (3.2.A) and regional information (3.2.R). A finished-product plant is written into the drug product branch, under manufacture (P.3), and for biotech products into an appendix as well.
Under manufacture, P.3.1 is where the name, address and responsibility of each manufacturer and each proposed production site involved in manufacturing and testing should be provided. In P.3.3 the guideline says equipment should, at least, be identified by type and working capacity, where relevant, and that in certain cases environmental conditions should be stated; low humidity for an effervescent product is its example.
For biotech products, 3.2.A.1 on facilities and equipment adds a manufacturing flow diagram and the design features that prevent contamination, such as area classifications.
So a blender of another type, a new working capacity or a relaxed humidity condition on site belongs in change control, checked against what the dossier says.