A recall procedure that has never been tried is an assumption with a document number.
EU GMP Chapter 8 covers complaints, quality defects and recalls, and most of what it says can be tested.
On complaints, it says appropriately trained and experienced personnel should be responsible for managing complaint and quality defect investigations, independent of the sales and marketing organization unless otherwise justified. If a quality defect is discovered or suspected in a batch, consideration should be given to checking other batches, and in some cases other products.
The recall clauses are more specific. Recall operations should be capable of being initiated promptly and at any time. Distribution records should be readily available to the persons responsible for recalls, with customer contact details inside and outside working hours. The effectiveness of the recall arrangements should be periodically evaluated too, for office hours and out of hours, with the evaluation documented and justified.
The chapter stops short of saying a mock recall has to be run. It says consideration should be given as to whether one should be performed.
A fair evaluation can be small. Take one shipped batch on a Saturday evening, ask the on-call person for its distribution list, and ring the out-of-hours numbers of the first three customers on it. Time the whole thing. The numbers that no longer answer are the finding.