A failed batch at the contract site needs an investigator, and the supply contract rarely names one.
That is the job of the quality agreement, which is usually the thinner of the two documents.
EU GMP Chapter 7, on outsourced activities, says there must be a written contract that clearly establishes the duties of each party. The contract should specify the communication processes and describe clearly who undertakes each step. The FDA's 2016 guidance on contract manufacturing uses the name most of us use: quality agreement.
Read yours against this list.
- Responsibilities for each GMP activity, as a table: purchasing of materials, testing, batch record review, release. One owner per row.
- Changes: which ones the contract site must notify, and which need approval before they are made. Chapter 7 says the acceptor should not make unauthorised changes outside the terms of the contract.
- Deviations and out-of-specification results: what is reported, to whom and how fast, as a number of working days.
- Audit rights and subcontracting. Chapter 7 says the contract should permit the contract giver to audit, and the acceptor should not subcontract without the giver's prior evaluation and approval.
- Records and release: who keeps which records, for how long, and who certifies the batch.
The reporting time is the usual weak spot. "Promptly" is in many agreements, and each side has its own idea of prompt.