A one-page-per-risk CCS storyboard

  • Life Sciences
  • 1 min read

A CCS usually spans dozens of documents: URS, SOPs, monitoring reports, deviation files. The inspector has one day.

Annex 1 (2022) lists what a CCS should consider, from premises and utilities to personnel, cleaning and monitoring, and in a real plant those topics are owned by different people and written in different places. Trouble starts in the inspection room, when someone asks how a given risk is controlled and the answer takes three people and twenty minutes of searching.

A storyboard fixes the presentation without rewriting the strategy. One page per contamination risk, each carrying:

  1. The risk, in one sentence, and where in the process it arises.
  2. The design controls: airflow, pressure cascade, barriers, material and personnel flows.
  3. The procedural controls, by SOP number and revision.
  4. The monitoring that proves the controls work, with the latest trend on the page.
  5. The owner, open deviations or CAPAs, and when the board was last reviewed.

The boards point to the controlling documents rather than copying them, so they stay short and do not drift out of date. Walk the inspector through the boards in process order and each question lands on one page.

On Humiley's Life Sciences projects the CCS is the organizing document from the design stage, so the storyboards have something coherent to point at.

More engineering notes on our news page

Industries

Related

More on this subject

The CCS is where design decisions get defended

Under EU GMP Annex 1 (2022), the Contamination Control Strategy has to connect barriers, airflow, personnel and material flows, cleaning, utilities and monitoring. A useful test for any CCS: every line should point to a drawing, calculation or test, not to a procedure written after construction.

Read

Both states are required; only the stage is a choice

A 50 m² Grade B room needs 10 classification locations under ISO 14644-1:2015, and EU GMP Annex 1 requires them at rest against ISO 5 and in operation against ISO 7, with the smoke study in both states. Whether each run sits in OQ or PQ is for the URS and risk assessment to justify.

InsightRead