Annex 11: accuracy checks on manual entries

  • Life Sciences
  • 1 min read

An operator types a new alarm limit for a cold room into the EMS. 8.0 °C goes in as 80, and nothing on the screen objects.

After that the room can warm to 15 °C in silence, and the audit trail will show a valid change by an authorised user. Data integrity controls protect what was entered. They cannot tell whether it was the right number.

That gap is what clause 6 of the 2011 text of EU GMP Annex 11, Accuracy Checks, is about. Where critical data are entered manually, there should be an additional check on their accuracy. The check may be done by a second operator or by validated electronic means. How critical the data are, and what a wrong entry could cause, should be covered by risk management.

That third sentence does the sorting. A comment field is not critical data. An alarm limit, a setpoint, a calibration offset or a recipe value usually is, and the risk assessment should name them.

For a BMS or EMS the electronic route is often the easier one to live with: a permitted range on each critical field, so that 80 is refused where the limit must lie between 2 and 10, and a confirmation step that shows old and new value before the change is accepted. A second person at the screen works too, but only as well as the night shift is staffed.

Either way it starts as a line in the URS. A check added after validation is a change.

Industries

Related

More on this subject

GMP on the electrical side

Where a SCADA, BMS or EMS records GMP-relevant data, access control, clock synchronization, alarm records and audit trails are decided by the electrical and automation engineers. Many sites keep those parameters on a separate validated EMS. Humiley's cross-functional training covers GMP, validation and project management.

InsightRead

Part 11 starts with the predicate rule

Part 11 applies to electronic records that a predicate rule such as 21 CFR 211 requires. For a BMS or EMS, name the rule behind each point: GMP-critical monitoring usually belongs in a validated EMS. For EU export, Annex 11 has no predicate-rule test, so the BMS still needs a risk assessment.

InsightRead

Replacing an EMS: migrate the data before the old system goes

When an environmental monitoring system is replaced, years of records move with it or become unreadable. List the records and retention periods, specify what moves, verify a trial migration, migrate under change control and keep the old data readable. The 2011 text of Annex 11 says validation should include checks on value and meaning.

InsightRead