A time-stamped audit trail under 21 CFR 11.10(e) is only as reliable as the clock behind it. Restrict date and time changes to administrators at the operating-system level, synchronize to the site NTP server with an alarm on failure, log every clock change, and test the restriction in OQ.

InsightRead

PIC/S PI 041-1 expects system administrator rights to sit apart from people who generate or approve GMP data, where possible. On small sites one engineer often does both. The conflict can be controlled: named separate accounts, admin activity reviewed by QA or IT, and configuration changes through change control.

InsightRead

What a printed EMS trend leaves out

FDA's 2018 data integrity Q&A separates static records from dynamic ones. A printed EMS trend keeps one view and leaves raw values, metadata and the audit trail behind. Keep the electronic original for the retention period, have the reviewer work in the system, and label printouts as convenience copies.

InsightRead

PIC/S GMP and EU GMP: who issues the certificate

The PIC/S GMP Guide and EU GMP are almost identical, revised Annex 1 included. In the EU the GMP principles are set in law and certificates sit in EudraGMDP; PIC/S authorities adopt the guide nationally and PIC/S certifies nothing. One design serves both; the EU inspection route is planned separately.

InsightRead

When an environmental monitoring system is replaced, years of records move with it or become unreadable. List the records and retention periods, specify what moves, verify a trial migration, migrate under change control and keep the old data readable. The 2011 text of Annex 11 says validation should include checks on value and meaning.

InsightRead

A true copy is a copy of an original record that has been verified, by a dated signature or a validated process, to hold the same information, including context, content and structure. The MHRA guidance of 2018 says it may be retained in place of the original if a documented system is in place to verify and record the integrity of the copy.

InsightRead

Life Sciences

Quality Culture

In GMP guidelines (WHO, EU, PIC/S), you will find requirements for equipment, facilities, and personnel—but you won’t find a chapter called “Quality Culture.” And yet, it’s often the very first thing inspectors (auditors) sense the moment…