First air and the smoke study that proves it

  • Life Sciences
  • 1 min read

A particle counter in a Grade A zone can read well under its limit while the air reaching an open vial has just passed over a glove.

Grade A is set by particle count: no more than 3,520 particles of 0.5 µm and larger per m³, ISO 5 at rest and in operation. The counter samples at one fixed point and reports how clean the air is there. Where that air went before reaching the product is outside what it measures.

First air is filtered air that has touched nothing between the HEPA face and the open container. Once it sweeps over a gloved hand or a stopper bowl it carries whatever it picked up, while the probe nearby still samples clean air.

An in-operation smoke study shows the path. It should include the interventions: clearing a fallen stopper, changing a tub, taking an environmental monitoring sample. Film it, and watch for air moving from glove to open container.

Where it does, the corrections are physical and procedural. Interventions move to the side of or downstream of open product, hands stay out of the space between filter and container, and the findings go into the Contamination Control Strategy next to the monitoring plan. A filler layout is hard to change once installed, so the expected airflow is worth reviewing against the intervention list at design stage too.

Industries

Related

More on this subject

Fixed-speed FFUs slow down as their HEPA loads

A fixed-speed fan filter unit loses airflow as its HEPA filter loads. Set at 0.45 m/s, it has 20% to lose before the 0.36 m/s bottom of the Annex 1 guidance range. Constant-airflow EC units hold velocity if they are selected at the final pressure drop, and their speed trend doubles as a filter-loading record.