GMP wants air to flow out of the clean room. Biosafety wants it to flow into the room that holds the organism.
A live-organism suite has to satisfy both.
Product protection puts the processing room highest. Containment puts the room with the organism lowest, so leaks run towards it and away from the corridor. One cascade direction for the whole suite gives up one of the two, so the compromise is carried by the airlock between room and corridor.
A sink airlock is held below the room and the corridor. Air enters from each side and leaves through the airlock's own exhaust. Room air cannot reach the corridor, and the room can still sit positive to its airlock for the product.
In a bubble arrangement the airlock is held above both neighbours on clean supply air, which spills into the room and into the corridor. Air from the room cannot travel past it to the corridor, and corridor air cannot reach the room. It costs more supply air, and the room sits below its airlock.
In both cases the containment argument rests on the door interlock. With both doors open, the airlock separates nothing and air moves between room and corridor from whichever side is higher. The risk assessment should say what happens then, and who the alarm reaches.
Each step needs a measurable differential, typically 10–15 Pa between adjacent grades, with Annex 1 guidance of at least 10 Pa.