A Grade C room with a high air change rate still cannot protect an open vial.
Mixing lowers the average count; it does not carry a particle away from one point.
Unidirectional airflow does that job, and Annex 1 gives it a guidance speed of 0.36–0.54 m/s at the working position. The speed reading shows the parallel streams are fast and even at the measuring plane. Whether they still sweep past the needle with an operator's arm over the vial, or whether a machine guard or a return grille bends them back, only shows up in the smoke study, and inspectors will ask to watch the film.
For a mixed-flow room the useful number is how fast dilution works. The ISO 14644-3 recovery test raises the particle count and times its fall to one hundredth, the 100:1 recovery time. That result is set against the clean-up period the site has justified for getting back to at-rest limits after operations. A room already inside it gains little from more air changes except fan energy.
The two go wrong in opposite directions. Air changes get added to a mixed-flow room in the hope of protecting open product, and unidirectional ceilings get fitted in a Grade C room where nothing in the process is exposed.