Plenty of CCS drafts spend pages on airflow and a single paragraph on water.

EU GMP Annex 1 (2022) puts water systems inside contamination control. Section 6 expects WFI to be produced, stored and distributed in a way that minimizes the risk of microbial growth, and gives constant circulation above 70 °C as an example.

Keeping a loop hot and moving shapes most of its design. The branch to each user valve has to be short enough that the water in it stays hot. ASME BPE asks for a dead leg of no more than twice the branch diameter (L/D ≤ 2), measured from the inside wall of the main; older designs worked to a looser 6D rule taken from the pipe centreline. The loop needs turbulent flow at the furthest user point, sanitization by heat or pure steam planned before the layout is fixed, and temperature and TOC sensors on the return, where they report on the whole loop rather than the tank.

The CCS then has to argue for all of that as it argues for the HVAC: what could contaminate the water, which design feature stops it, what monitoring would show it failing, and what qualification proves on day one. A loop frozen before anyone wrote that down tends to get described in the CCS instead of justified.

We design PW, WFI and pure steam alongside the cleanroom HVAC, under the same CCS.

Industries

Related

More on this subject

Performance Beyond the Surface

Cleanroom surfaces look like a finishing trade and behave like a performance system. Wall, floor and ceiling finishes decide whether a room can be cleaned to its classification, how long it survives a sporicidal regime, and how much particulate it sheds back into the air it was built to keep clean.

InsightRead

WHO's 2022 sterile GMP and the barrier decision

WHO's 2022 GMP for sterile products (TRS 1044, Annex 2) follows EU Annex 1. For a WHO-prequalification plant the barrier comes first: a RABS needs a Grade B background, a closed isolator Grade D, and that sets the HVAC. The contamination control strategy should be written alongside the design.

InsightRead