A new mixer went in under site change control. Open the registered process description and it describes the old one.
Nobody skipped a step. Engineering assessed the installation, QA assessed the GMP impact, and the form had no line asking what the marketing authorisation says about this piece of equipment. The gap surfaces months later, when someone lays the registered process description beside a batch record.
ICH Q10 is direct about it. Proposed changes should be evaluated relative to the marketing authorisation, and there should be an assessment to determine whether a change to the regulatory filing is required under regional requirements. It names Regulatory Affairs among the areas whose expertise should evaluate a proposed change. EU GMP Annex 15 (2015) lists regulatory status among the things a planned change should be evaluated against.
In practice that is a few small additions to the change control procedure. The form asks, for every change, whether the dossier describes the item being changed. Regulatory affairs is an assessor on the form and is asked at the proposal stage. Where a filing is needed, its category is settled before the change is implemented, because ICH Q12 separates changes that require prior approval from those that are notified.
Engineering's part is to ask the question while the purchase order is still a draft.
Topics
Industries