As-built classification on a new cleanroom suite

  • Life Sciences
  • 1 min read

ISO 14644-1 defines three occupancy states. Annex 1 grades use two of them, and a new suite reaches the third one first.

As-built means the installation is complete, with all services connected and working, but no production equipment, no materials and no people. It is the state a suite is in after the HVAC is balanced and before the process equipment arrives. Classifying the rooms then is legitimate under ISO 14644-1, and on a new project it is often the most informative test you will run.

An as-built result tells you whether the air handling, the terminal filters and the room envelope can reach the class on their own. If an empty room fails, the fault is in the HVAC, a filter or a leak path, because nothing else is in there to blame. That is far easier to sort out before a filling line is bolted to the floor.

It cannot tell you anything about the equipment. Machines add heat, shed particles, block the supply air and leave dead zones behind their guards. An empty room has none of that. Nor does it say anything about people, who account for most of the difference between at rest and in operation.

As-built therefore belongs in the commissioning or OQ plan as a construction acceptance test. The GMP classification is still done at rest, with the equipment installed and standing by, and then in operation. A report that files the as-built result as the at-rest classification will be questioned.

More on our news page

Industries

Related

More on this subject

Set a device assembly room's class from the product's risk

ISO 13485 §6.4.2 asks for documented contamination control without naming a cleanroom class. Setting the class from sterilisation method, patient contact and bioburden sensitivity often lands device assembly at ISO 8, with ISO 7 only where needed, less air than Grade C, a smaller AHU and a reason an auditor can read.

InsightRead

Energy savings and the requalification bill

Energy measures that change validated cleanroom conditions go through Annex 15 change control. Classification alone can mean 10 sample locations for a 50 m² room, at rest and in operation, before recovery tests and a CCS update. Price that next to the kWh, or design reduced modes in and qualify them once.

InsightRead

Environmental monitoring locations and their rationale

Classification spreads sampling points evenly by floor area; environmental monitoring should go where contamination would reach open product first. Place particle probes and settle plates from the smoke study, the intervention list and a documented risk assessment, keep them clear of the flow, cover the last-to-recover spots, and reference the evidence behind each point.

InsightRead