WHO's 2022 GMP for sterile products (TRS 1044, Annex 2) was drafted in step with EU Annex 1.
A plant aimed at WHO prequalification now starts from the same design choices, and the first is the barrier at the filling line. Both texts favour RABS or isolators around the critical zone and expect the choice to be justified. That choice sets the grade of the room around it. Under Annex 1 a RABS stands in a Grade B background, a closed isolator in at least Grade D and an open isolator in at least Grade C. Background grade drives air change rates, gowning, the number of airlocks and the size of every AHU, so it has to be settled before anyone sizes one.
Then comes the document that explains it all. The WHO text asks for a contamination control strategy, as Annex 1 does, tying premises, airflow, barriers, utilities, monitoring and qualification together with the reason for each decision. Writing it after the drawings are frozen usually means hunting for reasons behind decisions nobody recorded.
A project budgeted against the earlier WHO text (TRS 961, Annex 6) is worth re-checking on both points before it goes to tender.
We write the URS, validation strategy and qualification roadmap in parallel with the design, with the target market fixed in the design basis on day one.