Annex 15 on cleaning validation: more than the previous product

  • Life Sciences
  • 1 min read

Every swab for the active came back below its limit. Nobody had set a limit for the detergent.

Most cleaning validation protocols are built around one residue, the previous product. Section 10 of EU GMP Annex 15 (2015) has a sentence for the detergent too: limits should be established for the removal of any cleaning agents used. "It rinses off" stays a belief until a rinse sample has been tested with a method that can see the detergent.

Two more sentences widen the study further. The risk presented by microbial and endotoxin contamination should be considered when the protocol is developed. And the time between manufacture and cleaning, and between cleaning and use, should be taken into account to define dirty and clean hold times. Equipment that was chemically clean on Friday and left wet over the weekend is a different object on Monday. Product dried on for three days does not clean like product washed off within the hour.

The engineering is in dead legs that hold the final rinse, and in whether the equipment drains and dries.

Does your cleaning validation master plan set a limit for the detergent?

Industries

Related

More on this subject

CPV: one abbreviation, two different things

Continued process verification is the FDA's Stage 3: assurance during routine production that the process remains in a state of control. EU GMP Annex 15 (2015) calls it ongoing process verification. Continuous process verification, defined in ICH Q8(R2), is an alternative approach to validation. Write the phrase out and cite its source.

InsightRead

CTD Module 3 describes the plant you are building

The CTD has five modules, and Module 3 (Quality) records the process, its controls and often the facility, including room grades, water grades and the conditions behind hold times. After approval, changing them generally needs a variation. Draft Module 3 and the design basis from one table and send every change to both teams.

InsightRead

GEP: what qualification can rely on, and what it repeats

Good engineering practice is the design review, installation checks and commissioning that sit under qualification. WHO's HVAC guideline defines it, and EU GMP Annex 15 (2015) allows data from outside the manufacturer's own programs if justified and controlled. Commissioning sheets made with calibrated instruments and signed by the person who measured can then be relied on.

InsightRead