USP <800>: the 5 Pa pressure window in a hazardous-drug compounding room

  • Life Sciences
  • 1 min read

Under USP <800>, rooms for compounding hazardous drugs are held 2.5 to 7.5 Pa negative to their neighbours. The whole window is 5 Pa.

Cytotoxics are among the hazardous drugs it covers, and it gives the pressure in inches. The containment room must be at a negative pressure between 0.01 and 0.03 inches of water column relative to all adjacent areas. One inch of water is about 249 Pa, which gives roughly 2.5 to 7.5 Pa. The room must also be externally vented, with at least 12 or 30 air changes per hour depending on the type of room.

USP <800> is a US standard; local hospital-pharmacy rules decide what applies on a site in Viet Nam.

A cascade step between cleanroom grades in a pharmaceutical plant is typically 10 to 15 Pa. Here the pressure has an upper limit, and it sits below that range.

The lower limit is containment: air moves into the room, so drug particles and vapours stay in. For the upper limit we can only give our own reading. Where the room is also an ISO Class 7 buffer room for sterile work, pulling it harder draws unfiltered air through the door frame, the ceiling and every service penetration.

So the transmitter has to resolve single pascals, and the room has to be tight, because the leaks are where unfiltered air gets in.

Hospital clean zones, compounding pharmacies among them, are part of our Life Sciences work. Questions on a pharmacy project: contact@humiley.com

Industries

Related

More on this subject

Grade C through a fab engineer's eyes

To a semiconductor engineer, Grade C at ISO 8 in operation looks loose. EU GMP Annex 1 adds microbial limits: 100 CFU/m³ in air, 50 per settle plate over 4 hours, 25 per contact plate. Rooms wiped with sporicide need floors and joints a fab never had to clean, and a CCS that ties the choices together.

InsightRead

ISO Class 1 vs ISO 5: counting at 0.1 µm

ISO Class 1 allows 10 particles of 0.1 µm and larger per cubic metre; ISO 5 allows 100,000 at that size. At that level the installed leak scan must prove frames and grid, not just the U15 filter, single-digit counts need large sample volumes, and airborne molecular contamination needs its own sampling plan.

InsightRead

Pharma habits in a battery dry room

In a Li-ion dry room at −60 °C dew point and below, extra air changes do not help: return air often passes back through the desiccant rotor, so more supply air means a bigger rotor and more regeneration heat. Size airflow from the moisture balance; pressure control, airlocks and envelope sealing carry over from pharma.

InsightRead