Skip to content

Renewable Energy

Dew point tolerances in °F: leave out the offset

  • Renewable Energy
  • 1 min read

A ±2 K dew point tolerance converted to ±35.6 °F has picked up an offset it should never have had.

Dual-unit dry-room specifications are common on battery projects. The parent company or the cell equipment supplier writes in °F, the desiccant dehumidifier data and the local design documents are in °C, and both versions have to agree down to the alarm limit.

Two different sums are involved. An absolute temperature or dew point uses °F = °C × 1.8 + 32, so −60 °C is −76 °F. A difference uses the 1.8 factor alone, and a band of ±2 K is ±3.6 °F. Add the 32 by habit and it becomes ±35.6 °F, odd enough to catch if someone reads that line closely. A deadband or a rate of change converted the same wrong way is harder to spot, because the result can look plausible.

Rounding causes the quieter mismatch. Round the °F column to whole degrees and keep one decimal in °C, and the two limits no longer describe the same room, while the dehumidifier was selected against only one of them. Pick the controlling column, convert from it, and say in the document that it governs.

Humiley designs dry rooms to −60 °C dew point and below.

When your two columns disagree, which one wins?

Related

More on this subject