FFU filters: change from the room or from above

  • Manufacturing & Distribution
  • 1 min read

Whichever way an FFU filter is changed, the cleanroom below it stops.

The new HEPA gets an installed leak test before the room returns to service, scanned from the room side across the filter face and seal, then cleaning and recovery. So the choice between top-side and room-side replaceable filters is about where the rest of the work happens and what it disturbs.

A top-side change needs a walkable ceiling or a service void a technician can work in, often among cable trays and sprinkler pipes. Opening the unit from above stirs up dust settled in the plenum, and the new filter is seated by feel because the gasket is out of sight. The old, loaded filter never passes through the room.

A room-side filter drops out of the unit face into the cleanroom. Nobody goes above the ceiling and the technician can see the seal as the filter goes in. The loaded filter comes out inside the classified space, so the cleaning after the change has more to deal with.

The leak test needs planning in both cases. The aerosol has to be introduced upstream of the filter and its upstream concentration measured, so the unit needs an injection point and an upstream sampling port reachable without lifting ceiling panels. Ask the supplier where they are before ordering.

In a pharma suite with a solid ceiling and no walkable void, room-side filters are usually the only practical option.

How are filters changed in your cleanrooms today, from above or below?

Related

More on this subject

ISO Class 1 vs ISO 5: counting at 0.1 µm

ISO Class 1 allows 10 particles of 0.1 µm and larger per cubic metre; ISO 5 allows 100,000 at that size. At that level the installed leak scan must prove frames and grid, not just the U15 filter, single-digit counts need large sample volumes, and airborne molecular contamination needs its own sampling plan.