Grade A air speed is measured where the product is

  • Life Sciences
  • 1 min read

Annex 1 gives Grade A air speed as a range, 0.36–0.54 m/s, and names where it applies: at the working position.

That second half is the one that gets lost. Many qualification reports show velocities taken just below the filter face, because the traverse is easy there and the readings are steady. The product is somewhere else: at the needle, the stopper bowl, the open vial, often a metre or more further down, with arms, tools and machine guards in between.

Unidirectional air slows and spreads as it travels, and it bends around obstacles. A unit that sits comfortably inside the range at the filter face can drop below 0.36 m/s at working height, or turn turbulent behind a guard. The smoke study shows this. The filter-face reading does not.

Annex 1 calls the range a guidance value and accepts another value if it is scientifically justified in the CCS. That is a useful freedom with a duty attached: the CCS should say where the working position is, how the speed is measured there, and how the airflow visualization correlates with the measurement.

We write those measurement points into the URS and the OQ protocol at design stage, so the test answers the argument the CCS makes.

Industries

Related

More on this subject

Zero growth and the HVAC record around a media fill

Annex 1 sets zero growth as the APS target, and any contaminated unit fails it. The environmental side of the investigation starts from viable monitoring, with HVAC and EMS trends as support, so review trends before the fill, confirm logging and clock sync, and agree which HVAC events count as interruptions.

InsightRead

Annex 1 has applied since 25 August 2023

The revised EU GMP Annex 1 has applied since 25 August 2023, with point 8.123 following in 2024. A site still planning its gap assessment is years behind. Most findings land in the CCS, for example a pressure alarm delay set at commissioning that nobody can justify.

InsightRead