Green hydrogen starts with a water plant

  • Renewable Energy
  • 1 min read

Each kilogram of electrolytic hydrogen starts as at least 9 kg of water. That is stoichiometry, before any treatment losses.

The losses are real. If the reverse osmosis stage recovers 75% of its feed, those 9 kg of permeate need 12 kg going in before polishing. The raw-water figure on a green hydrogen site is set by the treatment train, and the electrolyser supplier's feedwater limit, usually a conductivity figure, sets how far that train has to go.

Engineers who have built pharmaceutical purified-water systems will recognise most of the job. Several habits carry straight over: sizing the plant for the reject stream as well as the product, a written sampling plan with points, frequencies and an owner, online conductivity at the electrolyser feed that is alarmed and trended, and buffer storage sized on how long the water plant may be down before production stops.

Some habits should stay in the pharma plant. Many electrolysers polish their own feed internally, so a hot-sanitized, orbital-welded loop built to a no-dead-leg rule can be more than the supplier asks for. Read the supplier's feedwater specification and warranty terms first and build the loop to them. WFI practice can fill in details where the specification is silent.

Clean utilities are part of our engineering work, and green hydrogen facilities sit in our renewable-energy scope. Talk to an engineer: contact@humiley.com · +84 28 7777 6668 (Viet Nam office)

Related

More on this subject

UHP piping: the pipe is a cleanroom too

High-purity PVDF joined like ordinary plastic pipe leaves fusion beads that trap bacteria, so fab UPW loops use bead-and-crevice-free joints. UHP gas lines add electropolished 316L, orbital welds with coupons, helium leak tests and outlet particle, moisture and oxygen checks. Pharma WFI practice shares much of the discipline.