How to correct a GMP record

  • Life Sciences
  • 1 min read

One straight line through the wrong entry, the original still readable, then the new value with initials, date and reason.

That is a good GMP correction, all of it.

EU GMP Chapter 4 sets it out. Any alteration to an entry on a document should be signed and dated, the alteration should permit the reading of the original information, and the reason should be recorded where appropriate.

The versions we still find in commissioning and maintenance records:

  • correction fluid, or a label stuck over the original
  • a value overwritten so the 3 might be an 8
  • a scribble that blacks out the first entry completely
  • a correction with no date, by someone whose initials are not on the signature list
  • a reason like "error" on a test result, which explains nothing

An inspector does not treat any of these as small. Each makes the record impossible to reconstruct, which is what ALCOA+ is there to prevent. A reason of a few plain words, such as "transcription error, value from instrument display", costs ten seconds and closes the question.

Engineering and site teams write a large share of the GMP records in a new plant, so this belongs in their induction as much as in QA's. At Humiley, GMP is part of the cross-functional training for engineers, alongside validation and project management.

How we work across design, delivery and qualification

Industries

Related

More on this subject

A month-end note from Tony Nguyen, CEO

After more than twenty years with automation vendors and running an EU-GMP EPC contractor, Tony Nguyen saw problems start at the handovers between companies rather than inside any one scope. This note explains why Humiley is organized as one accountable team across design, project management, equipment and maintenance.

InsightRead

GEP: what qualification can rely on, and what it repeats

Good engineering practice is the design review, installation checks and commissioning that sit under qualification. WHO's HVAC guideline defines it, and EU GMP Annex 15 (2015) allows data from outside the manufacturer's own programs if justified and controlled. Commissioning sheets made with calibrated instruments and signed by the person who measured can then be relied on.

InsightRead