A HEPA housing you cannot scan cannot pass a leak test

  • Manufacturing & Distribution
  • 1 min read

The validation team arrives with an aerosol generator and a photometer.

The terminal HEPA housing has no upstream injection point and no way to sample the upstream concentration.

At that point the installed leak test cannot be done properly, and a filter that passed at the factory cannot be shown to be leak-free where it matters: in the ceiling.

The test itself is simple, and ISO 14644-3 describes it. Challenge the filter with aerosol upstream, measure the upstream concentration, then scan the whole downstream face and the perimeter seal with a probe. With a photometer, a reading above 0.01% of the upstream concentration is commonly treated as a leak.

Three details on the housing decide whether that is possible:

  1. An upstream aerosol injection point and an upstream sample port, reachable without dismantling the ceiling.
  2. A seal that can be scanned: a knife edge in gel, or a clamped gasket, with the frame joint exposed to the probe.
  3. A diffuser or grille that comes off without disturbing the filter.

Leaks at the frame and seal are a frequent finding, so a housing that hides the seal hides one of the most likely failures.

Specify terminal housings from the test backwards: if it cannot be scanned, keep it off the drawing.

Related

More on this subject

Both states are required; only the stage is a choice

A 50 m² Grade B room needs 10 classification locations under ISO 14644-1:2015, and EU GMP Annex 1 requires them at rest against ISO 5 and in operation against ISO 7, with the smoke study in both states. Whether each run sits in OQ or PQ is for the URS and risk assessment to justify.

InsightRead

AMC limits: name the compound, then the unit

HEPA and ULPA filters do not stop airborne molecular contamination, and an AMC limit written only as "1 ppb" is a different mass for every compound: about 0.70 µg/m³ for ammonia, 1.49 µg/m³ for hydrogen chloride. A fab URS should name the compound, the unit with its reference temperature, and the sampling method.

InsightRead

An SOP register answers the change-control question

An SOP register should record, for each SOP, the owner, version, review date and every document it refers to. Humiley's template covers 536 SOPs across 20 departments. The cross-reference column tells a change control which documents a revision touches, and review dates keep superseded versions out of use.

InsightRead