At OQ, a Grade C door designed for 15 Pa can turn out to have an alarm band copied from an older drawing.
The design differential sits on the room data sheet (RDS), and months later someone else turns it into alarm limits, a trend and an operator response in the pressure-cascade monitoring SOP. Nobody is asked to compare the two until the qualification team does it for them.
In the meantime they drift. A drawing revision can change a door's design value without anyone updating the SOP, or an SOP edit can widen an alarm band outside change control. Occasionally the low limit ends up under the 10 Pa that Annex 1 gives as guidance between adjacent grades.
The check before OQ needs one table with a row for every door: the RDS revision the system was balanced to, the design differential on it, and the high and low alarm limits in the current SOP. Any row where the numbers disagree traces back to one of those two gaps, and a document change now costs less than a deviation raised during OQ.