Grade A microbial limits for EU and US filings

  • Life Sciences
  • 1 min read

Grade A air under Annex 1 (2022): 'no growth'. Under FDA's 2004 aseptic guidance, ISO 5 air has an action level of 1 CFU/m³.

On paper those look almost the same. Written into two SOPs, they can lead to different behaviour at the bench.

FDA's Table 1 sets ISO 5 action levels of 1 CFU per cubic metre of air, and 1 CFU per settle plate over 4 hours where plates are used. The guidance adds that samples from ISO 5 areas should normally yield no microbiological contaminants. Read literally, a single colony reaches the action level.

Annex 1 goes further in its wording. Grade A limits are 'no growth' for air, settle plates, contact plates and glove prints, any growth in Grade A is investigated, and the organism is identified to species level.

A plant supplying both markets does not need two rules. Write the stricter one once:

  1. Any recovery in Grade A is an excursion, investigated and trended, whatever the count.
  2. Every Grade A isolate is identified to species level.
  3. Batch impact is assessed against the interventions and the EM results at that location.

HVAC evidence feeds the third step. When an isolate turns up, the first questions are whether first air was intact at that point and what the pressure and particle trends showed during the fill.

Humiley fixes the destination market in the design basis on day one, because the market decides which evidence the plant must be able to produce.

Industries

Related

More on this subject

PIC/S GMP and EU GMP: who issues the certificate

The PIC/S GMP Guide and EU GMP are almost identical, revised Annex 1 included. In the EU the GMP principles are set in law and certificates sit in EudraGMDP; PIC/S authorities adopt the guide nationally and PIC/S certifies nothing. One design serves both; the EU inspection route is planned separately.

InsightRead

Annex 1 initial validation of an aseptic process needs at least 3 consecutive successful simulations covering all working shifts, then periodic runs twice a year per process, line and shift. The cleanroom must hold its qualified state throughout. Agree an HVAC freeze date with QA, and list in advance which jobs are like-for-like and which need an impact assessment.

InsightRead