Skip to content

Life Sciences

Part 11 or Annex 11: fix the destination market on day one

  • Life Sciences
  • 1 min read

Part 11 wants the printed name, date and meaning on every e-signature. Annex 11 wants a plan for when the system is down.

21 CFR Part 11 is a US regulation on electronic records and electronic signatures: when they can be trusted in place of paper. EU GMP Annex 11 covers computerized systems across their whole lifecycle, from risk management and supplier assessment to periodic evaluation, business continuity and archiving.

They overlap heavily. Both expect validated systems, controlled and attributable access, and audit trails the recorded user cannot switch off. The differences show up in the documents:

  1. Part 11 is specific about electronic signatures: the printed name, the date and time and the meaning of each signature, linked so it cannot be copied onto another record.
  2. Annex 11 expects a documented, risk-based lifecycle, with supplier assessment, periodic review of each system and a plan for when the system is down.

For a BMS, an environmental monitoring system or a SCADA on a new plant, this matters on day one. With the destination market fixed in the design basis, the URS, supplier questions and validation plan are written once. Added later, the same system is often revalidated with new paperwork.

Fix the destination market in the design basis before any automation vendor is selected.

Industries

Related

More on this subject

GMP on the electrical side

Where a SCADA, BMS or EMS records GMP-relevant data, access control, clock synchronization, alarm records and audit trails are decided by the electrical and automation engineers. Many sites keep those parameters on a separate validated EMS. Humiley's cross-functional training covers GMP, validation and project management.

InsightRead

ALCOA+ on the EMS is a design requirement

Environmental monitoring and BMS data that support GMP decisions must meet ALCOA+. In practice that means individual logins, time-synchronized controllers, an audit trail users cannot disable, alarms acknowledged with name and comment, and tested backups, with GMP-critical parameters separated early onto a validated system.

Read

When the EMS server fails mid-fill

EU GMP Annex 11 (2011) clause 16 expects documented, tested continuity arrangements for systems supporting critical processes. For an environmental monitoring system that means knowing whether counters buffer and back-fill, who takes manual readings, who decides to stop a fill and how quickly the server can be restored.

InsightRead