WHO's 2022 technology transfer guideline in brief

  • Life Sciences
  • 1 min read

WHO replaced its 2011 technology transfer guideline in 2022. The current text is Annex 4 of Technical Report Series 1044.

It begins before any document changes hands. The first steps should include due diligence and a gap analysis, with visits to both units. The analysis should cover personnel, premises, equipment and instruments, utilities, cleaning, quality control, documentation and computerized systems. For an engineer, that sentence is the scope of the site survey.

Responsibilities get one plain sentence: those of both units, the sponsor and the marketing authorization holder should be defined in writing.

On equipment the guideline asks for a side-by-side comparison of working principle, capacity, make and model. Utilities such as HVAC, gas and water systems should have sufficient capacity for the process being transferred.

Analytical procedures should be transferred along with the product.

The item most often left to the end is written up front: acceptance criteria for a successful transfer should be documented a priori, in the transfer protocol.

Every clause above says "should": this is guidance.

Talk to an engineer: contact@humiley.com · +84 28 7777 6668 (Viet Nam office)

Topics

Industries

Related

More on this subject

Annex 1 sets zero growth as the APS target, and any contaminated unit fails it. The environmental side of the investigation starts from viable monitoring, with HVAC and EMS trends as support, so review trends before the fill, confirm logging and clock sync, and agree which HVAC events count as interruptions.

InsightRead

30% of what? Fix the baseline first

An HVAC energy saving is only as good as its baseline. Hold room limits, weather file, production and cleaning schedules and airflow justification identical in both models, and define the baseline system in writing, for example with ASHRAE 90.1 Appendix G, before quoting any percentage.

InsightRead

A CCS nobody reviews is only a snapshot

Annex 1 expects the Contamination Control Strategy to be actively reviewed and updated. A yearly meeting catches changes late. Adding one question to every HVAC change control, EM adverse trend review and deviation closure form, asking whether the CCS still says the right thing, keeps it current with the site.

InsightRead