Pure steam quoted at "3 bar" can mean steam that saturates near 144 °C or near 134 °C, and datasheets rarely say which.
The difference is atmospheric pressure, about 1.013 bar. At 3 bar gauge the steam is at about 4 bar absolute and saturates near 144 °C. At 3 bar absolute it saturates near 134 °C. Roughly 10 °C separates two readings of the same line.
For a sterilizer that decides whether the cycle can run. A 134 °C cycle needs saturated steam at about 3.04 bar absolute in the chamber, roughly 2 bar gauge, plus whatever the supply pipework loses on the way. A generator delivering 3 bar gauge has margin to spare. One delivering 3 bar absolute cannot reach the cycle temperature at all, and that shows up at the first OQ run rather than in the bid review.
Instruments carry the same trap. A transmitter ranged 0–6 bar reads gauge or absolute depending on its model code, and swapping one for the other of the same range puts the reading off by about 1 bar on the first day.
The discipline costs nothing. Put a suffix on every pressure in the URS and on every datasheet you issue, bar(g), bar(a), kPa(g), psig or psia, and send a question back whenever a vendor document says only "bar".
PW, WFI and pure steam systems are part of our engineering scope, designed alongside the cleanroom HVAC.
Has a missing g or a ever cost one of your projects an OQ run?