Four pages, one each for schedule, cost, earned value and risk, are enough for an owner's monthly project report.
Each page works only if its top line answers the owner's question. Anything longer tends to stop being read above the project engineer.
- Start the schedule page with the critical path and the milestones the owner has promised to someone else. Then what moved since last month, and why. The full program belongs in an appendix.
- On cost, the figure that matters is forecast at completion against budget, with every pending change order listed and priced.
- Earned value needs SPI and CPI with a three-month trend. SPI is earned value over planned value; CPI is earned value over actual cost. A CPI of 0.9 means each dong spent is buying 90% of the work it was planned to buy. Agree the trigger at the start, for example a review when either index stays below 0.95 for two months running; one month alone is often invoice timing.
- Risks come from the live FMEA register: the top items, each with an owner and a date, marked new or closed.
A slipped long-lead item, a change order waiting for approval or a mitigation past its date belongs on page one, even when it is embarrassing. The owner may have a board or a regulator to warn.
Our EPCM monthly reports cover schedule, cost, earned value and risk, and the FMEA register behind them is reviewed weekly.