Bracketing and matrixing get used as one word. They cut stability testing in two different ways.
Take a product in three strengths and three bottle sizes, with three batches of each. A full design puts all 27 combinations on test at every time point.
Bracketing, as ICH Q1D (2002) defines it, tests only the samples at the extremes of a design factor, such as strength or container size, at all time points as in a full design. In the guideline's own example the lowest and highest strengths in the smallest and largest bottles go on test, which is 12 of the 27. The design assumes that the intermediate levels are represented by the extremes.
Matrixing tests a selected subset of all the possible samples at one time point and another subset at the next; at the first and last time points, all selected combinations should be tested. Its assumption is a different one: the subset tested stands for all samples at that time point.
The smallest and largest packs are not automatically the extremes: where container size and fill both vary, ICH Q1D says that should not be assumed. The guideline also says the use of a reduced design should be justified, and that the risk of ending with a shorter shelf life than a full design would support should be considered.
The design belongs to the stability and regulatory team. The plant meets it later, as shelf space in the stability chambers.
Topics
Industries




