Annex 1 leaves Grade B particle sampling frequency and sample size to the site, provided they catch rising contamination.
Grade A is monitored continuously through critical processing. For Grade B an inspector will ask how the numbers were chosen.
Start from what the monitoring has to see: people entering, material transfer into the room, interventions at the Grade A boundary, a door or a pressure step that fails. Each of those has a duration, and the sampling has to be shorter.
A sequential system makes the point. With 8 ports sampled one minute each, the counter comes back to the same point about every 8 minutes, purge time aside. A door event lasting 3 minutes at one point can fall entirely between two samples.
Set the program in this order:
- Locations first, from the smoke study and the layout: beside the openings into Grade A, at doors from Grade C, where operators stand.
- Frequency from the shortest event that matters at each point. Critical points may need their own counter.
- Sample volume large enough that a count at the ≥ 5 µm alert level means more than one or two particles.
- The justification written down: recovery times and counts from qualification, the trend so far, and a rule that raises the frequency after a change.
On our Life Sciences projects the CCS is the organizing document, and this rationale belongs in it.