A specification that says "test to ISO 14644-3" has named a menu of eleven tests and ordered none of them.
Part 3 of ISO 14644 lists supporting tests and gives a method for each. Classification by particle concentration is not among them. That is ISO 14644-1, which Part 3 says shall be carried out to classify a room. Everything else is a supporting test: air pressure difference, airflow, airflow direction and visualization, recovery, temperature, humidity, installed filter system leakage, containment leak, electrostatic and ion generator, particle deposition, and segregation.
The 2019 edition is plain about their status. The tests may not all be required for any given project, and tests and methods should be selected in a manner agreed between the customer and the supplier.
That agreement is where test scopes go wrong. The contractor prices the shortest reading of that line in the specification, and the argument starts at handover, when QA asks for a recovery test nobody planned.
Part 3 supplies the methods. The list of tests, the occupancy state for each and the acceptance criterion have to be written into the test specification before a contractor prices it.