A common misreading: "risk-based requalification" means you can stretch the interval if nothing has gone wrong. It works the other way.
EU GMP Annex 1 (2022) sets maximum intervals: 6 months between requalifications for Grade A and B cleanrooms, 12 months for Grade C and D. A risk assessment can justify testing more often, or adding tests, where the process or the monitoring history calls for it. It is not a route to longer gaps in a sterile suite.
What a periodic requalification retests:
- Classification by particle count to ISO 14644-1.
- Filter integrity: installed HEPA leak test by aerosol scan.
- Airflow volume.
- Pressure differentials between adjacent rooms and grades.
- Air velocity: required for filling zones under unidirectional airflow, and set by the CCS risk assessment in Grades B, C and D. In rooms without unidirectional airflow, a recovery test replaces the velocity test.
The calendar is not the only trigger. A filter replacement, an AHU modification or a layout change goes through change control and may need partial requalification whatever the date is.