A Grade B room never retested for recovery after its supply ductwork changed is the kind of gap an inspector can write up in an afternoon.
Six months before an inspection, fixing it is ordinary work: a budget line, a shutdown window and a change control. The reason to look early is that the site still decides what gets fixed first, and nothing arrives with a response deadline attached.
A written gap review gives the site that list. Take the regulation that applies, Annex 1 (2022) for a sterile site, and read it clause by clause against the facility, the CCS and the records. Each gap becomes one row in a table with five columns: the clause, what exists today, the risk, a proposed fix and a rough size. Sorting that table by risk and size is most of the planning.
In practice the rows mix documents and hardware. A CCS that lists the environmental monitoring points but never explains them against the airflow the smoke study showed. A cascade that holds on the BMS screen and fails when doors cycle at shift change. A pass box interlock nobody has challenged since handover.
It helps if the reviewer neither designed nor runs the facility, and the table should be finished before an inspection date is set.