Choosing the worst-case product for cleaning validation

The 2015 text of EU GMP Annex 15 allows a worst-case product approach to cleaning validation if a scientific rationale is provided; criteria may include solubility, cleanability, toxicity and potency. Put them in a table per product, with the PDE and the residue load, and reopen it when a new product arrives.

InsightRead

Metadata: what a stored value needs to mean anything

A stored value of 22.4 means nothing without its sensor tag, unit, time stamp, status flag, author and audit trail. The MHRA's 2018 data integrity guidance defines metadata as data that describe the attributes of other data and provide context and meaning. Test that backups, exports and migrations carry them.

InsightRead

Why cleanroom airflow is called unidirectional

At 0.45 m/s across a 1 m clean zone the Reynolds number is about 30,000, far beyond laminar flow. ISO 14644-1 and the 2022 EU GMP Annex 1 use the term unidirectional airflow: steady velocity, roughly parallel streams. It is tested by air speed, uniformity and smoke studies, so write it that way in the URS.

InsightRead

How to qualify a cleanroom testing contractor

Cleanroom testing is often bought late and on price, and QA first meets the tester as a signature on a report. Before the order, hold evidence of tester training, calibrated instruments, method statements to ISO 14644-1 and ISO 14644-3, a sample report and agreed raw data practice, then list the tester as an approved supplier.

InsightRead

EU GMP Annex 15 (2015) says a formal release for the next qualification stage should be authorised, and that conditional approval to proceed can be given where there is a documented assessment of no significant impact on the next activity. That assessment is made item by item, against the tests that follow.

InsightRead

OOS and OOT: two results, two different triggers

An out-of-specification result falls outside the specification or acceptance criteria and starts with a laboratory assessment. An out-of-trend result is inside the limits but breaks the pattern of earlier results. EU GMP Chapter 6 says both should be addressed and investigated, which needs data recorded so that trends can be evaluated.

InsightRead

Concurrent validation is the exceptional route

EU GMP Annex 15 (2015) accepts concurrent validation in exceptional circumstances, where there is a strong benefit-risk ratio for the patient. The decision must be justified, documented in the validation master plan and approved by authorised personnel. A project that is running late does not meet that test.

InsightRead

How to plan a smoke study

EU GMP Annex 1 (2022) says airflow pattern studies should be performed at rest and in operation, with video recordings retained. A usable study starts as a plan: locations and interventions from the risk assessment, defined runs, fixed camera and smoke positions, a script with acceptance criteria per shot, and a QA review.

InsightRead

Engineering Solution & Consultancy

Cut the SKU list before the transfer starts

Each SKU left on a transfer list has to be covered by validation and stability work. Before the transfer, list the SKUs with volume and market, group them by formulation, process and pack line, retire or merge the tail, choose the extremes where bracketing is justified, and order the work by value and risk.

InsightRead

Leave time between SOP approval and effective date

An SOP that becomes effective the moment it is signed puts the next shift in deviation before anyone is trained. The 2011 text of EU GMP Chapter 4 says the effective date should be defined; the gap after approval is where training, the swap of controlled copies and the register update take place.

InsightRead