Cleaning validation: five steps, and sampling is the fourth

Sampling is the fourth step of a cleaning validation. Before any swab, EU GMP Annex 15 (2015 text) expects a justified worst-case product, a carryover limit based on a toxicological evaluation, and sampling locations with recovery shown for each surface and method. Hold times belong to the run, and manual cleaning should be confirmed at a justified frequency.

InsightRead

Why the registration batch should not be batch one

Dropping the trial batch makes the first batch a receiving site ever produces the one whose stability data goes into the dossier. ICH Q1A(R2) (2003) says the process used for primary stability batches should simulate the production process. Our advice is to run a trial batch first, compare it with the sending unit's data and fix what it shows.

InsightRead

ASTM E2500: who verifies, and whose documents count

Two ideas in ASTM E2500 shorten qualification. Subject matter experts plan, execute and review verification, and in ISPE's summary of the 2025 edition the quality unit approves the plans and the final acceptance. Vendor documentation may be used as evidence if the vendor has been assessed. EU GMP Annex 15 (2015 text) allows some FAT tests to stand at IQ/OQ where justified.

InsightRead

Nine determinations for accuracy, before and after ICH Q2(R2)

ICH Q2(R1) said accuracy should be assessed using a minimum of 9 determinations over at least 3 concentration levels. Q2(R2), adopted in November 2023, asks for an appropriate number and keeps 3 concentrations with 3 replicates as its example. The minimum of 9 remains under repeatability, and the confidence interval for accuracy should be compatible with the acceptance criterion unless otherwise justified.

InsightRead

A new pack size on a line that is already qualified

Adding a pack size to a qualified packaging line is a change. Open a change control with a regulatory assessment, check format parts and settings against the qualified range, validate where the range moved, release artwork, codes and master data, then update the packaging instructions, the line clearance checklist and operator training.

InsightRead

Cpk 1.33: a convention, and what the GMP texts say instead

A Cpk of 1.33 puts the nearer specification limit 4 standard deviations from the process mean. It is a statistical convention: EU GMP Annex 15 (2015 text) and the FDA guidance of 2011 recommend statistical tools and name no index. With 10 batches the confidence interval is wide, so report the batch count and the interval.

InsightRead

The 2013 text of EU GMP Chapter 1 lists the qualification status of relevant equipment and utilities among the items a product quality review should include. Engineering can make that line believable with four more inputs: changes in the period, excursions and trends, calibration and maintenance failures with product impact, and the status of engineering CAPAs.

InsightRead

Batch history is not a process validation

Tabulating twenty or thirty past batches was once called retrospective validation. The 2015 text of EU GMP Annex 15 (section 5) says it is no longer an acceptable approach: a traditional process should undergo prospective validation, with concurrent validation only in exceptional circumstances. The batch history belongs in ongoing process verification.

InsightRead

The 2011 text of EU GMP Annex 11 (clause 6) says that where critical data are entered manually there should be an additional check on their accuracy, by a second operator or by validated electronic means. For a BMS or EMS alarm limit, a permitted range on the field and a confirmation step are the practical answer.

InsightRead

Batches of one product run back to back leave more baked-on product, packed fines and microbial growth for the final clean. The 2015 text of EU GMP Annex 15 (clause 10.9) says the maximum length of a campaign, in time and/or number of batches, should be the basis for cleaning validation. Set that maximum and validate after it.

InsightRead