Under the 1999 edition of ISO 14644-1, a 100 m² cleanroom needed 10 classification sampling locations. Under the 2015 edition it needs 16.
The old rule was a square root: the number of locations was the square root of the floor area, rounded up. The 2015 revision replaced it with Table A.1, which reads the count straight from the area and climbs faster for mid-sized rooms. For 100 m² the table gives 16. Above 1,000 m² a formula takes over from the table.
Two other things changed at the same time. The 95% upper confidence limit calculation, which applied to rooms with two to nine locations, was dropped. And the room is now divided into sections of roughly equal area with one location in each, so the plan has to show where every point sits, not only how many there are.
On a running site this shows up in the requalification plan. Plans written before 2016 often still carry the old counts, and nobody notices until an auditor lays the plan beside the standard. The extra points also cost counting time: six more set-ups and sample runs on a 100 m² room, every time it is requalified.
Check the location count in your classification SOP against Table A.1 before the next requalification, not during it.