Most gap trackers have a status column, and the word in it that causes trouble later is "closed".
Months after a gap assessment, an inspector or a new QA head picks a finding and asks how it was closed. If the answer is a work order number and an engineer's memory, the gap is still open as far as anyone else can tell.
The evidence that closes a gap should be agreed before the work starts, and it differs with the kind of gap.
A design gap, such as an undersized extract or a missing airlock, is fixed on paper first. Expect a drawing issued at a new revision, the calculation behind it updated, and a change control record that points to both.
For a room that failed its pressure differential, a repair proves nothing until the test is run again by the method that found the gap, with calibrated instruments, and the result is attached.
A missing alarm response step is a procedural gap. It closes when the revised SOP is approved and effective and the operators have training records against the new revision. A missing calibration certificate is simpler: find or regenerate it and file it with the system's records.
Whatever the type, the closure is signed by someone other than the person who made the fix, usually QA.