Annex 1 (2022) Table 6 sets Grade B maximum action limits: 10 CFU/m³ air, 5 CFU per settle plate over 4 hours, 5 per contact plate and 5 per glove print. Alert levels must sit below them and come from your own trend data, starting with a documented judgement in a new facility.
21 CFR 211.42 and 211.46 and EU GMP Chapter 3 ask for adequate ventilation, air control and filtration, but give no air change rate or pressure differential, and no filter class beyond HEPA for aseptic areas. Those come from Annex 1, FDA's 2004 aseptic guidance, ISO 14644 and the designer's justification, recorded in the design basis.
In a Li-ion dry room at −60 °C dew point and below, extra air changes do not help: return air often passes back through the desiccant rotor, so more supply air means a bigger rotor and more regeneration heat. Size airflow from the moisture balance; pressure control, airlocks and envelope sealing carry over from pharma.
Annex 1 expects Grade A/B staff to be reassessed for gowning at least annually. When the same people keep failing, check the change room before retraining: a clear dirty/clean line, space to gown, stations in SOP order, and a final stage at the grade of the room it serves.
EU GMP Annex 1 gives Grade A unidirectional air speed as 0.36–0.54 m/s, a guidance value, at the working position. Readings taken just below the filter face can miss the drop and turbulence at working height. Define the measurement points in the URS, OQ protocol and CCS.
Changing from WHO-GMP to EU-GMP midway through design reopens the URS, validation master plan, DQ and drafted IQ/OQ protocols, and for sterile products the Annex 1 CCS. The market is one of five scoping questions, with the process, grades and room list, existing assets and the division needed first.
A 50 m² Grade B room needs 10 classification locations under ISO 14644-1:2015, and EU GMP Annex 1 requires them at rest against ISO 5 and in operation against ISO 7, with the smoke study in both states. Whether each run sits in OQ or PQ is for the URS and risk assessment to justify.
EU GMP Annex 1 (2022) sets no ≥5 µm limit for Grade A classification, following ISO 14644-1:2015, but keeps a monitoring limit of 29 per m³ and asks for investigation of repeated low counts. Switching the 5 µm channel off breaks the second rule without anyone noticing.
EU GMP Annex 1 calls separate entry and exit change rooms for Grade B desirable. One room saves area but relies on procedure at the busiest shift change; two rooms give one-way flow at the cost of doors, air and qualification. On a new build, start from two.
A spreadsheet that calculates F0, an assay result or an airflow figure is a computerized system under EU GMP Annex 11 once its answer drives a GMP decision. Locked formula cells, one released template under version control and formulas checked once by hand are the minimum an auditor will look for.
EU GMP Annex 1 expects the final stage of an airlock to be, at rest, the same grade as the cleanroom it leads into. Into Grade B, that means 3,520 particles of 0.5 µm per m³, terminal HEPA supply, its own pressure step and a place in environmental monitoring, not a transfer grille.
EU GMP Annex 11 (2011) clause 16 expects documented, tested continuity arrangements for systems supporting critical processes. For an environmental monitoring system that means knowing whether counters buffer and back-fill, who takes manual readings, who decides to stop a fill and how quickly the server can be restored.