The manufacturing license, the GMP certificate and the dossier often spell the same site three ways, and an assessor cannot know they are one place. Keep a one-page master statement of the legal name, official address and building identifiers, copy every regulatory document from it, and change it only under change control.
A supplier audit that ends when the report is filed tends to find the same observations next time. For audits of active substance suppliers, EU GMP Chapter 5 says required corrective and preventive actions should be implemented. Classify each observation, agree an action and date with the supplier, verify the evidence, and show open actions on the approved supplier list.
Batches of one product run back to back leave more baked-on product, packed fines and microbial growth for the final clean. The 2015 text of EU GMP Annex 15 (clause 10.9) says the maximum length of a campaign, in time and/or number of batches, should be the basis for cleaning validation. Set that maximum and validate after it.
Outlet dew point is the last thing to check on a new desiccant dehumidifier. First confirm rotor direction, speed and seals, set and measure the process and reactivation airflows, and prove the heater and rotor interlocks. Then set the reactivation temperature and compare inlet and outlet dew point with the selection.
An electric heater in an AHU overheats when airflow stops. At the factory test, witness each link of its safety chain: the airflow interlock, the automatic-reset and manual-reset high-limit cut-outs, the fan run-on, the clearance to filters and sensors, and a contactor that can cut power if the solid-state relay fails conducting.
ICH M4Q(R1) divides the body of data in Module 3 into drug substance, drug product, appendices and regional information. A finished-product plant appears under manufacture in the drug product branch, where equipment type and working capacity should be identified, and, for biotech products, in the facilities and equipment appendix.
EU GMP Annex 1 (2022) asks for an integrity test of final filters at requalification and puts no age on the filter. A terminal HEPA is replaced when a leak cannot be repaired within site limits, when pressure drop reaches the manufacturer's final value, or after damage or wetting. On glass-fibre media, dust loading alone does not lower efficiency.
A room taken out of use without paperwork keeps alarming and keeps printing maintenance tasks. Treat it as a change: assess the neighbouring pressures, archive the final records and monitoring data, isolate utilities and cap ducts, update the asset register, maintenance plan and calibration schedule, and formally retire the monitoring points.
Designer, supplier, contractor and maintenance team each hold part of a facility's design intent, and assumptions get lost at every boundary. Humiley works as four divisions on one design basis, so the drawing, the factory acceptance test and the maintenance plan all trace back to the same requirements.