SU and RU: the two parties in a technology transfer

  • Engineering Solution & Consultancy
  • 1 min read

WHO's technology transfer guideline names two parties, the SU and the RU, and defines neither of them as a company.

The sending unit is "the involved disciplines at an organization from where a designated product, process or method is expected to be transferred". The receiving unit is the same sentence with "where" in place of "from where". Both definitions are in the glossary of TRS 1044, Annex 4.

The phrase to notice is the first one. A unit is production, quality control, engineering and anyone else who touches the product at that site, so two plants of one group have an SU and an RU just as two companies do. The guideline calls these intracompany and intercompany transfers.

Each unit has duties against its name, and the guideline says their responsibilities should be defined in writing. The SU should assess the suitability and degree of preparedness of the RU before transfer; the RU should be able to accommodate the intended production capacity.

For engineers the RU's duties reach the plant room. The guideline says utilities such as HVAC, gas and water systems should have sufficient capacity and be appropriate for what is being transferred.