Company news from Humiley Group INC and technical notes on cleanroom HVAC, GMP validation, semiconductor environments and energy-storage engineering.

  • 780 articles

Everything

From the Humiley newsroom

85 articles tagged #Annex1.

21 CFR 211.42 and 211.46 and EU GMP Chapter 3 ask for adequate ventilation, air control and filtration, but give no air change rate or pressure differential, and no filter class beyond HEPA for aseptic areas. Those come from Annex 1, FDA's 2004 aseptic guidance, ISO 14644 and the designer's justification, recorded in the design basis.

InsightRead

When gowning fails, walk the change room

Annex 1 expects Grade A/B staff to be reassessed for gowning at least annually. When the same people keep failing, check the change room before retraining: a clear dirty/clean line, space to gown, stations in SOP order, and a final stage at the grade of the room it serves.

InsightRead

Read Annex 1 clause by clause before the inspection date

A Grade B room never retested for recovery after a ductwork change is an easy inspection finding, and six months earlier it is ordinary planned work. A written review reads Annex 1 clause by clause and gives each gap one row: clause, current state, risk, fix and rough size, finished before an inspection date is set.

InsightRead

EU GMP Annex 1 gives Grade A unidirectional air speed as 0.36–0.54 m/s, a guidance value, at the working position. Readings taken just below the filter face can miss the drop and turbulence at working height. Define the measurement points in the URS, OQ protocol and CCS.

InsightRead

Both states are required; only the stage is a choice

A 50 m² Grade B room needs 10 classification locations under ISO 14644-1:2015, and EU GMP Annex 1 requires them at rest against ISO 5 and in operation against ISO 7, with the smoke study in both states. Whether each run sits in OQ or PQ is for the URS and risk assessment to justify.

InsightRead

≥5 µm in Grade A: classification vs monitoring

EU GMP Annex 1 (2022) sets no ≥5 µm limit for Grade A classification, following ISO 14644-1:2015, but keeps a monitoring limit of 29 per m³ and asks for investigation of repeated low counts. Switching the 5 µm channel off breaks the second rule without anyone noticing.

InsightRead

EU GMP Annex 1 calls separate entry and exit change rooms for Grade B desirable. One room saves area but relies on procedure at the busiest shift change; two rooms give one-way flow at the cost of doors, air and qualification. On a new build, start from two.

InsightRead

Requalification and calibration usually run on separate schedules with separate owners. Put them on one calendar: calibrate room sensors before requalifying, check test instrument certificates at pre-test approval, and assess the impact on every result when a sensor fails calibration.

InsightRead

EU GMP Annex 1 expects the final stage of an airlock to be, at rest, the same grade as the cleanroom it leads into. Into Grade B, that means 3,520 particles of 0.5 µm per m³, terminal HEPA supply, its own pressure step and a place in environmental monitoring, not a transfer grille.

InsightRead

Barrier glove integrity: checks, tests, failures

Isolator and RABS gloves need a visual check at every use and a physical integrity test, usually pressure decay, at defined frequencies. A pinhole passes the first and fails the second. Write in advance what a failed glove triggers: which batches are assessed, which records are pulled, who decides and when the glove is replaced.

InsightRead