The SKU list is a design input

Annual tonnage sizes the granulation suite. The SKU list sizes much of the rest: changeovers per week and so the number of packaging lines, pallet positions, the printed materials store, storage for format parts, and which rooms can share air handling. Ask for it, with ranges, before the layout is frozen.

InsightRead

Shall, should, may, can: reading a standard's verbs

In ISO and IEC standards, shall states a requirement, should a recommendation, may a permission and can a possibility. Normative annexes bind; nothing in an informative annex, a note or an example has to be met to claim conformity. EU GMP is different: it is written in 'should' and still expected. Check the verb and the annex before quoting a clause.

InsightRead

One more market is one more SKU to run

'Same product, new box' brings new artwork and codes to control, a registration that may need stability data at other climatic conditions, possibly a new pack to qualify, and one more changeover in the weekly plan. Cost the SKU as a small project before a launch date is promised.

InsightRead

Annex 11 and the BMS-to-EMS link

The 2011 text of Annex 11 (clause 5) says systems that exchange data electronically should include built-in checks for correct and secure entry and processing. On a BMS-to-EMS link we read that as status flags, a communication watchdog, end-to-end checks of units and time stamps, and a loss-of-communication test in the qualification.

InsightRead

When 'read and understood' is the only training

A signature under 'read and understood' shows that reading happened. EU GMP Chapter 2 says training should be appropriate to the duties assigned and its practical effectiveness should be periodically assessed. Practical tasks need demonstration, supervised practice and an observed assessment, with SOPs sorted by risk to make that affordable.

InsightRead

A 75% RH fixed point from table salt

A saturated sodium chloride slurry in a sealed container holds the air above it at about 75% RH at 25 °C; magnesium chloride gives about 33%. The two points show whether a humidity probe has drifted between calibrations. It is a field check and does not replace a traceable calibration.

InsightRead

Five things a quality agreement has to settle

The supply contract covers price and delivery. The quality agreement has to settle who is responsible for each GMP activity, how changes are notified and approved, how fast deviations and OOS results are reported, audit and subcontracting rights, and who keeps records and certifies the batch.

InsightRead

Knowledge management in ICH Q10, in plain terms

ICH Q10 names knowledge management as one of two enablers of the pharmaceutical quality system: a systematic approach to acquiring, analysing, storing and disseminating information about products, processes and components. In a technology transfer, that means handing over the reason behind each parameter, along with the batch record.

InsightRead

Cleaning validation does not follow the SKU count

Cleaning validation follows the residue and the equipment train. SKUs that differ only in pack share one bulk product, and EU GMP Annex 15 allows a justified worst-case product across a group. Changes between SKUs on the packaging line are controlled by line clearance under Chapter 5.

InsightRead

How to read one row of the ASHRAE 170 table

Each hospital room type has one row in the ASHRAE 170 design parameters table, and every column is a design input: pressure relationship, outdoor and total air changes, whether air is exhausted outdoors, whether room units may recirculate, filtration, humidity and temperature. Read the notes, and check which edition applies.

InsightRead

A URS line such as 'alarm on low room pressure' cannot be tested as written. The functional specification says how the system will behave, function by function. In the usual V-model it faces OQ, so it should be numbered and approved before configuration starts, not reconstructed by the tester from the running system.

InsightRead

The 2013 text of EU GMP Chapter 1 and 21 CFR 211.192 speak of recording and investigating deviations, and neither gives a number of days. The 30-day limit is the site's own, and inspectors hold a site to its procedure. The alternative is also a site rule: a limit per risk class, with extensions only on a written reason and an interim risk assessment.

InsightRead