GMP sets no 12-month calibration interval

Neither the 2015 text of EU GMP Chapter 3 nor 21 CFR 211.68 sets a 12-month calibration interval. The first asks for defined intervals by appropriate methods, the second for a written program, and ISO/IEC 17025 keeps the laboratory from recommending an interval unless agreed. The site sets it from criticality and as-found history, and records why.

InsightRead

When the root cause is 'human error' and the action is retraining

A deviation closed as human error with retraining tends to return, because what made the slip easy is still there. The 2013 text of EU GMP Chapter 1 says human error as a cause should be justified, with system causes not overlooked. Change the form, the label or the step, then check for recurrence.

InsightRead

WHO's 2022 technology transfer guideline in brief

WHO's technology transfer guideline (TRS 1044, Annex 4, 2022) starts before any document moves: due diligence and a gap analysis at both sites, responsibilities defined in writing, equipment compared side by side, analytical procedures transferred with the product, and acceptance criteria documented a priori. Each of these is a "should".

InsightRead

Engineering Solution & Consultancy

What makes a SKU in pharma

A SKU is one uniquely identified sellable item: a product in one strength, dosage form, pack size and pack type for one market. One tablet in two strengths, four pack sizes and five markets is 40 SKUs. It is a commercial term, yet each SKU has to match what is registered.

InsightRead

Scale-up is more than a bigger batch size

Five times the batch at the same set-points gives different granules, because some parameters depend on scale. WHO's technology transfer guideline says batch sizes should be compared and the impact assessed where they differ. Compare the equipment, check dust, exhaust and water at the new scale, and settle set-points with trial batches.

InsightRead

Choosing the worst-case product for cleaning validation

The 2015 text of EU GMP Annex 15 allows a worst-case product approach to cleaning validation if a scientific rationale is provided; criteria may include solubility, cleanability, toxicity and potency. Put them in a table per product, with the PDE and the residue load, and reopen it when a new product arrives.

InsightRead

Metadata: what a stored value needs to mean anything

A stored value of 22.4 means nothing without its sensor tag, unit, time stamp, status flag, author and audit trail. The MHRA's 2018 data integrity guidance defines metadata as data that describe the attributes of other data and provide context and meaning. Test that backups, exports and migrations carry them.

InsightRead

Why cleanroom airflow is called unidirectional

At 0.45 m/s across a 1 m clean zone the Reynolds number is about 30,000, far beyond laminar flow. ISO 14644-1 and the 2022 EU GMP Annex 1 use the term unidirectional airflow: steady velocity, roughly parallel streams. It is tested by air speed, uniformity and smoke studies, so write it that way in the URS.

InsightRead

ICH Q10: two management reviews with two subjects

ICH Q10 describes two management reviews. Section 3.2.4 covers process performance and product quality over the lifecycle; section 4.1 covers the pharmaceutical quality system itself, its objectives and its performance indicators. Deviations on a line belong in the first, the time taken to close deviations in the second.

InsightRead

30 °C / 75% RH: what Zone IVb asks of a stability chamber

Long-term stability storage for hot, very humid markets is 30 °C ± 2 °C and 75% RH ± 5% RH, Climatic Zone IVb. The ASEAN guideline accepts short door-opening spikes; excursions over 24 hours should be described in the study report. The chamber's mapping and alarm history become part of the stability evidence.

InsightRead

How to qualify a cleanroom testing contractor

Cleanroom testing is often bought late and on price, and QA first meets the tester as a signature on a report. Before the order, hold evidence of tester training, calibrated instruments, method statements to ISO 14644-1 and ISO 14644-3, a sample report and agreed raw data practice, then list the tester as an approved supplier.

InsightRead