ICH Q10 names knowledge management as one of two enablers of the pharmaceutical quality system: a systematic approach to acquiring, analysing, storing and disseminating information about products, processes and components. In a technology transfer, that means handing over the reason behind each parameter, along with the batch record.
A supplier's standard IQ/OQ protocol was written for the standard machine, before your URS existed. EU GMP Annex 15 (2015) says site personnel should confirm its suitability before approval, and that vendor protocols may be supplemented. Trace each URS line to a test, then write a short supplementary protocol for the lines left uncovered.
On the road to registration, facility, utility and equipment qualification sits before the registration batches: fix products and markets in the design basis, qualify, make the batches on qualified equipment, run stability and submit. Where process validation and the inspection fall depends on the region and the process. A delay in PQ moves the earliest submission date.
Results dated before the protocol's approval signature suggest the acceptance criteria were written with the results known. EU GMP Annex 15 (2015) speaks of approved protocols and pre-defined criteria. Start testing after the last signature, justify any earlier data in the plan, and handle tests already run early as a deviation.
Good engineering practice is the design review, installation checks and commissioning that sit under qualification. WHO's HVAC guideline defines it, and EU GMP Annex 15 (2015) allows data from outside the manufacturer's own programs if justified and controlled. Commissioning sheets made with calibrated instruments and signed by the person who measured can then be relied on.
A terminal HEPA filter passes its factory test and is then carried through a building site. Clean the room and run on pre-filters first, unpack at the point of use, check the label against the position schedule, tighten evenly, then leak-scan the installed filter to ISO 14644-3 and record the serial number against its position.
A process validated at the sending site was validated with that site's equipment, utilities and people. WHO's technology transfer guideline defines validation batches as those produced by the receiving unit, and EU GMP Annex 15 (2015) covers site transfers. The earlier validation supports the new protocol. With bracketing, the number of batches could be reduced; the content of the previous validation should be available.
Five points of EU GMP Annex 15 (2015) shape a cleaning validation protocol: all product contact equipment, residue limits based on a toxicological evaluation, dirty and clean hold times, dedicated equipment or other appropriate measures where cleaning is ineffective, and manual cleaning confirmed at a justified frequency. All five are written with 'should'.
Hold time is the established period a material may be held under specified conditions and remain within specification. WHO's guidance says the study should use the production container, or a simulated one, and the same environmental conditions as the quarantine area. The staging room's temperature and humidity record is therefore part of the claim.
O&M manuals are often accepted unread. Open the manual at one system you know and check that it describes the equipment as built, lists settings by tag, gives each maintenance task an interval and a method, lists spare parts with part numbers, and has fault-finding that starts from the symptom.
A lead-acid UPS battery that tests at 80% of rated capacity is due for replacement under the IEEE recommended practices. Size the battery for the autonomy needed at end of life, with an ageing factor of 1.25, and keep the battery room cool: a common rule of thumb halves design life for every 8 to 10 °C of extra heat.
EU GMP Annex 15 (2015) describes three approaches to process validation: the traditional one, with a justified number of batches under routine conditions; continuous process verification for products developed by quality by design; and a hybrid of the two. Ongoing process verification should follow whichever is used.