Company news from Humiley Group INC and technical notes on cleanroom HVAC, GMP validation, semiconductor environments and energy-storage engineering.

  • 780 articles

Everything

From the Humiley newsroom

128 articles tagged #HumidityControl.

CTD Module 3 describes the plant you are building

The CTD has five modules, and Module 3 (Quality) records the process, its controls and often the facility, including room grades, water grades and the conditions behind hold times. After approval, changing them generally needs a variation. Draft Module 3 and the design basis from one table and send every change to both teams.

InsightRead

Keep the BMS outside the EMS validation boundary

When the BMS and the validated EMS share one platform, the validation boundary takes in the control logic and every setpoint change becomes change control. An EMS with its own sensors, database and QA alarms under Part 11 and Annex 11 allows the BMS to be managed under good engineering practice.

InsightRead

Dry air leaves the rotor hot: plan the post-cooling

Heat of adsorption and carry-over from the regeneration sector warm the air leaving a desiccant rotor. Size the post-cooler on rotor leaving temperature at full duty, treat it as a dry sensible coil, control room temperature on it and humidity on the rotor, and check the chilled water it needs.

InsightRead

A 75% RH fixed point from table salt

A saturated sodium chloride slurry in a sealed container holds the air above it at about 75% RH at 25 °C; magnesium chloride gives about 33%. The two points show whether a humidity probe has drifted between calibrations. It is a field check and does not replace a traceable calibration.

InsightRead

Reheat lowers the RH reading and leaves the water in the air. Before adding it, check outdoor dew point against design, chilled water temperature and valve position, and coil leaving dew point. Then look at reheat and the room sensor, and finally at doors, infiltration and new moisture sources.

InsightRead

Each hospital room type has one row in the ASHRAE 170 design parameters table, and every column is a design input: pressure relationship, outdoor and total air changes, whether air is exhausted outdoors, whether room units may recirculate, filtration, humidity and temperature. Read the notes, and check which edition applies.

InsightRead

The ICH stability guideline sets the accelerated study at 40 °C ± 2 °C and 75% RH ± 5% RH for a minimum of 6 months. If long-term studies run at 25 °C/60% RH, a significant change there should be followed by intermediate testing. For the chamber, excursions beyond the tolerances for more than 24 hours should be described in the study report.

InsightRead