An air shower blows loose fibres off the outside of a coverall and interlocks two doors. It does nothing about what operators shed from underneath. It earns its place at powder-area entries and interlocked routes, and it should never be the reason a gowning step disappears from the procedure.
A full-size 592 × 592 mm bag filter is commonly rated at about 3,400 m³/h. A 20,000 m³/h AHU needs six frames; a casing with room for four runs each at 47% over, with higher pressure drop, possibly lower efficiency and fluttering pockets. The frame count belongs in the specification and the FAT.
21 CFR 11.10(e) says record changes shall not obscure previously recorded information. A SCADA log that stores only the new setpoint fails on that phrase. Three tests before OQ: read the trail after a change, try to edit it as administrator, and compare its retention with the batch records.
When cooling and reheat valves open together at 20 ± 0.5 °C, the cause is usually a zero gap between the two control sequences. Check the trend first. Where the product data supports 20 ± 2 °C, cooling above 21 °C and reheat below 19 °C let the room drift between with both valves shut.
A fixed-speed fan filter unit loses airflow as its HEPA filter loads. Set at 0.45 m/s, it has 20% to lose before the 0.36 m/s bottom of the Annex 1 guidance range. Constant-airflow EC units hold velocity if they are selected at the final pressure drop, and their speed trend doubles as a filter-loading record.
Ten per cent on the load, on the airflow and on the coil multiplies to 1.33, because each margin sits on the one before. The oversized coil runs at part load most of the year, condenses less water, and RH climbs while temperature holds. One named margin and a part-load check avoid it.
21 CFR 11.200(a)(1) requires two distinct identification components for non-biometric signatures. Later signings in one continuous session must still use a component only the signer can execute, usually the password. Define the session and its timeout in writing, then test both cases at OQ.
A HEPA canopy protects the wound only where its air reaches it. A canopy sized to the table leaves trolleys outside the column, and a flat lamp head leaves a recirculating wake over the incision. A smoke study with lamps, trolleys and staff in position shows both.
An extra 100 Pa of filter resistance on a 10,000 m³/h supply costs about 460 W, roughly 4,000 kWh a year. The cheapest change point comes when the latest month's extra energy cost exceeds the average monthly cost since fitting, filter set included, provided it sits below the manufacturer's maximum final pressure drop.
A 0–10 V transmitter where the IO list says 4–20 mA passes a visual FAT and fails on site. That and four more defects (missing tags, gasket gaps, drain pans that hold water, missing documents) are worth checking at every AHU FAT against the approved specification and IO list.
When 5% of a 10,000 m³/h, 12 °C supply leaks into a 32 °C ceiling void, about 3.4 kW of sensible cooling goes with it and the room is 500 m³/h short. A named airtightness class, a pressure test before insulation and sealed joints and access doors keep that cooling in the duct.
A test at minimum fan speed with a door held open is OQ evidence; PQ shows normal operation, with production or a representative simulation, over a stated period. A step that forces a condition usually belongs in OQ, and separate protocols allow OQ to close before PQ starts.