UV-C on the coil does not take cleaning off the plan

UV-C lamps limit microbial growth on the coil surfaces the light reaches. They do not remove dust or scale from the fin pack, and lamp output falls with running hours. After fitting them, keep coil inspection and cleaning in the maintenance plan and add lamp hours, a replacement date and an interlock test.

InsightRead

Reading a thermography report for electrical panels

A thermal scan of a lightly loaded panel finds little, because heat at a bad joint rises roughly with the square of the current. Check the load recorded at the time of the scan, the line of sight, the emissivity setting, the comparison between phases, and that each finding has an image, a temperature difference and a severity.

InsightRead

EN 1822-1:2019 places E10, E11 and E12 filters in the EPA group, below HEPA. Their class rests on an efficiency determined on a statistical basis, and the standard says group E filters cannot and shall not be leak tested for classification. H13 and H14 filters are individually leak tested. Use EPA as a pre-stage.

InsightRead

Receiving HEPA filters: what to check before fitting

A HEPA filter leaves the factory tested, then travels by container, forklift and scaffold. Check the cartons on arrival, match label class, serial number and rated airflow to the schedule and test report, store dry within the stacking mark, open only at a clean work area and inspect media and gasket under strong light before fitting.

InsightRead

0.5%: the repair allowance EN 1822-4:2009 gave a new HEPA filter

EN 1822-4:2009, since replaced by EN ISO 29463-4, allowed a HEPA filter to be repaired and retested: all repairs together, whoever made them, up to 0.5% of the face area, none longer than 3.0 cm, unless buyer and seller agreed otherwise. Most purchase orders are silent. State whether repairs are accepted and have each one marked on the scan report.

InsightRead

N+1 on a fan wall datasheet is a claim until one fan is off. Without a backdraft damper, air runs back through the stopped fan, and with six fans the other five must each carry 20% more air with motor headroom to match. A single-fan-off step at FAT shows airflow, currents and recovery time.

InsightRead

An electric heater in an AHU overheats when airflow stops. At the factory test, witness each link of its safety chain: the airflow interlock, the automatic-reset and manual-reset high-limit cut-outs, the fan run-on, the clearance to filters and sensors, and a contactor that can cut power if the solid-state relay fails conducting.