Lactose, starch and microcrystalline cellulose are combustible dusts, and the granulation dust collector is one of the places that concentrates them. Test the blend for explosibility first, protect with venting, flameless venting or suppression plus inlet isolation, site the collector where a vent can discharge safely, then choose cartridge or bag media.
An OQ report can list certificates for every test instrument and none for the room pressure transmitters it reads. Before the first test, one sheet should cover both groups: certificate number, due date against the last test day and calibrated range against the test value, for the test kit and the installed sensors alike.
An AHU design copied from Ho Chi Minh City to a site near Hanoi can miss the heating coil and the humidifier. Use ASHRAE's heating dry-bulb column to size preheat, the humidification dew point column to size the humidifier, and the dehumidification columns for the cooling coil.
Many potent suites recirculate through safe-change HEPA housings; where the risk assessment rules that out, every cubic metre is tropical outdoor air. Run-around coils recover heat with the airstreams fully separated, wheels open a leakage path, and dedicated fresh-air pre-cooling targets the latent load. Our energy modeling targets a 30% HVAC energy reduction.
EU GMP Annex 1 does not predetermine in-operation particle limits for Grade D. Copying the at-rest 3,520,000 per m³ into that column can put the action level 8.8 times above a room's worst day. Set alert and action levels per room from PQ and routine data, and justify them in the CCS.
Warranty terms usually decide which chiller and AHU work goes to the OEM, and the split is rarely revisited. Keep compressor, refrigerant and firmware work with the OEM, bring filters, cleaning, trending and first response in-house, and file every service report in the site CMMS under change control.
Grade A allows 3,520 particles ≥ 0.5 µm per m³ at rest and in operation, and continuous monitoring shows it held. That only works if the sampling head sits near the point of fill facing the airflow, on short tubing that does not lose the ≥ 5.0 µm particles Annex 1 also limits.
Since April 2017, Ph. Eur. monograph 0169 permits WFI by non-distillation methods such as RO with further purification, with the same endotoxin limit of 0.25 IU/mL. The loop can still run hot; what changes is a generator at ambient, whose sanitization, integrity checks and online monitoring must be settled before the P&ID.
Annex 1 (2022) expects an aseptic process simulation to imitate routine processing with worst-case conditions. An APS run right after a filter change and rebalance tests a different process. Schedule maintenance away from APS runs and record the HVAC state for each run like the interventions.
Mixing air lowers the average particle count but cannot sweep a particle off an open vial. Unidirectional airflow is checked by air speed, with an Annex 1 guidance range of 0.36–0.54 m/s, and a filmed smoke study; a mixed-flow room by its 100:1 recovery time (ISO 14644-3).
PIC/S PI 041-1 expects system administrator rights to sit apart from people who generate or approve GMP data, where possible. On small sites one engineer often does both. The conflict can be controlled: named separate accounts, admin activity reviewed by QA or IT, and configuration changes through change control.
Two H14 filters from a new maker at 150 Pa initial pressure drop, fitted beside four originals at 110 Pa on one duct branch, take less air than their neighbours while the room total barely moves. Compare initial pressure drop before ordering, then change the whole set or retrim and measure every terminal.