Company news from Humiley Group INC and technical notes on cleanroom HVAC, GMP validation, semiconductor environments and energy-storage engineering.

  • 780 articles

Everything

From the Humiley newsroom

Announcements and company updates, alongside the technical notes our engineers publish from each practice.

A one-page-per-risk CCS storyboard

A contamination control strategy spread across dozens of documents is hard to present in one inspection day. A storyboard with one page per risk, carrying design controls, SOP references, monitoring trends, the owner and open CAPAs, gives the team a way to walk an inspector through it without rewriting the strategy.

InsightRead

Hygienic and commercial AHUs, side by side

Standing water under a cooling coil is the classic growth source in an AHU. A hygienic unit adds a drain pan that empties completely, smooth closed inner surfaces, full-size access doors, filter bypass class F9 to EN 1886, removable parts and a complete equipment file. Write each into the specification as a FAT check.

InsightRead

Who may change the clock on a GMP computer

A time-stamped audit trail under 21 CFR 11.10(e) is only as reliable as the clock behind it. Restrict date and time changes to administrators at the operating-system level, synchronize to the site NTP server with an alarm on failure, log every clock change, and test the restriction in OQ.

InsightRead

Panel temperature rise in a hot plant room

IEC 61439 temperature-rise verification assumes an ambient up to 40 °C with a 24-hour average of 35 °C. A hotter plant room is a special service condition the user should declare, so the builder verifies or derates for it. The specification should also size ventilation for the real losses and add drive heat.

InsightRead

Comparing chiller offers on part-load efficiency

AHRI's IPLV gives full-load efficiency a 1% weight, yet chiller offers lead with full-load COP. A 24/7 GMP plant in Viet Nam spends much of the year at part load, with condenser water warmer than the rating assumes. Ask for efficiency at each load point at your real condenser temperature.

InsightRead

Reading ISO 29463 HEPA labels against EN 1822

ISO 29463 labels encode efficiency: ISO 35H is at least 99.95% and ISO 45H at least 99.995%, the integral efficiencies of EN 1822 H13 and H14. ISO 40H sits between them with no EN 1822 name and passes twice as many particles at MPPS as 45H. Name the accepted equivalent in the specification.

InsightRead

Repair or replace an ageing AHU

A new coil and fan inside an old AHU casing keep every gap and hygiene defect of that casing. Pressure-test it against the EN 1886 class a new unit would meet and read the result by section: below plant-room pressure, gaps pull unfiltered air in, and worn filter frames let air bypass the filters.

InsightRead