Nine determinations for accuracy, before and after ICH Q2(R2)

ICH Q2(R1) said accuracy should be assessed using a minimum of 9 determinations over at least 3 concentration levels. Q2(R2), adopted in November 2023, asks for an appropriate number and keeps 3 concentrations with 3 replicates as its example. The minimum of 9 remains under repeatability, and the confidence interval for accuracy should be compatible with the acceptance criterion unless otherwise justified.

InsightRead

What a room pressure reading cannot tell you about containment

A potent-compound suite at −15 Pa shows which way air crosses the room boundary. It does not show what the operator breathes when a liner is cut or a drum is tipped. That takes air sampling in the breathing zone, and the equipment's containment performance is verified with a surrogate powder test.

InsightRead

Reading a thermography report for electrical panels

A thermal scan of a lightly loaded panel finds little, because heat at a bad joint rises roughly with the square of the current. Check the load recorded at the time of the scan, the line of sight, the emissivity setting, the comparison between phases, and that each finding has an image, a temperature difference and a severity.

InsightRead

A new pack size on a line that is already qualified

Adding a pack size to a qualified packaging line is a change. Open a change control with a regulatory assessment, check format parts and settings against the qualified range, validate where the range moved, release artwork, codes and master data, then update the packaging instructions, the line clearance checklist and operator training.

InsightRead

EPA filters (E10 to E12): the group below HEPA

EN 1822-1:2019 places E10, E11 and E12 filters in the EPA group, below HEPA. Their class rests on an efficiency determined on a statistical basis, and the standard says group E filters cannot and shall not be leak tested for classification. H13 and H14 filters are individually leak tested. Use EPA as a pre-stage.

InsightRead

When an instrument fails its as-found check, adjusting it straight away leaves two things unasked: how long it was wrong and what relied on it. Record the as-found values, find the last calibration that passed, list what depended on the readings since, have QA assess the impact, then adjust and review the calibration interval.

InsightRead

ISO 14644-3 is a menu of tests, and someone has to order

ISO 14644-3 lists eleven supporting cleanroom tests and gives a method for each, from air pressure difference to segregation. It says they may not all be required and that tests should be selected in a manner agreed between customer and supplier. The test specification has to name the tests, the occupancy state and the acceptance criterion before the work is priced.

InsightRead

Cpk 1.33: a convention, and what the GMP texts say instead

A Cpk of 1.33 puts the nearer specification limit 4 standard deviations from the process mean. It is a statistical convention: EU GMP Annex 15 (2015 text) and the FDA guidance of 2011 recommend statistical tools and name no index. With 10 batches the confidence interval is wide, so report the batch count and the interval.

InsightRead

The 2013 text of EU GMP Chapter 1 lists the qualification status of relevant equipment and utilities among the items a product quality review should include. Engineering can make that line believable with four more inputs: changes in the period, excursions and trends, calibration and maintenance failures with product impact, and the status of engineering CAPAs.

InsightRead